Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • General information

Actions are new cool feature which integrate our the feature that integrates our Smart devices. You can add Actions to different devices and create Actions between them.

Actions integrate device the devices added to the some same Aquarium, so please make sure that before you start to create Actions you have all the devices in assigned to the some same aquarium (menu on the left menu in the Smart Reef panel).

Info

In the example

...

below, we’ve set up an aquarium with the name

...

A Sps (new system) and

...

added a couple of our smart devices.

...

In this example we We are going to integrate Dosing pump with Kh Pump and Power switcher with KH keeper. Please make sure that your Dosing pump has minimum 0.5.5 firewarePump firmware is up to date.

You can update your device from the Smart reef panel but when you have issue with that you can find current fireware here: https://www.reeffactory.com/?state=productsDosingPumpTech on the bottom of the page.Manual how to update device using WiFi (you will need to have windows or mac laptop): https://www.youtube.com/watch?v=iIoq16KFk10Reef panel.

  • Compatible devices

We frequently update our devices and Smart reef panel. Some devices may be acquiring new Action features with the updates. Please check the list below:

Action triggering:

  • KH keeper

Action task execution

  • Dosing pump

  • Dosing pump Pro

  • Dosing pump x3

  • Dosing pump Large

  • Power switcher

Info

We will be informing users with official channels about new incoming, exciting changes and improvements in the Smart reef Action system.

  • Where to find the Actions panel

...

  • ?

It is in It’s available in the menu on the left menu in the Smart reef systemunder your tank, in this case, A Sps (new system).

...

When you click on

Status
titleActions
it takes you have the to this panel:

...

  • How to start using

...

  • Actions?

Please click ADD ACTIONNext you will have

Status
colourBlue
titleadd action

Next, the Action creation screen .should appear:

...

So on In this step it is required to choose Kh KH keeper:

...

Next step we : choose the command from the list:

...

The choise choice depends on usyou. If we you want to create the Action to add extra liquid when Kh the kH level is bellow below the desired level, then we choose Kh is bellow

Status
titleKH is below
. When we want to skip part of the next dose then please chose Kh choose
Status
titleKH is above
. In the example I , we will show you how both Actions work.

Please choose Kh keeper is bellow

Status
titleKH is below

Next please , enter a value (when Kh the KH keeper result will be bellow below the specyfic specific level of Kh your desired dkH then the system will add an extra dose)

For this example I typed 7 (Kh), we chose 7 dkH.

...

Then we select the pump for the integration (we can do the some same Action several times for different pumps)

...

For the example I have choosen the Kh In this example, we have chosen the kH pump

...

Next, we need to choose an Action which that will be triggered when Kh the dkH level is bellow 7 (if you typed other Kh level then it will start how you set it)below 7.

In this step, you can see all the avaible available Actions. So for the lower Kh dkH level, we can use

Status
titlemanual dose in ml
or
Status
titlemanual dose %
from the last dosingdose.

...

We will choose

Status
titlemanual dose %
from the last dosing dose - it This means that when you Kh your kH level will be bellow below the 7 Kh level (you can set it like you want to) kH level, then Dosing pump/s will add an extra dose - increased by % is based on the last dose.

...

For In this example I , we typed there 30% so when Kh the kH level is bellow below 7 the system will add an extra30% liquid calculated from the last dose. So if you your last dose (before measurement) was 9 ml then the Dosing pump will add extra 3 ml.

The

Status
titleEnter delay
are minutes of pump
function is the number of minutes the pump will delay. This feature is helpfull helpful when you have 2 or more pumps. We don’t want to add all the liquids at one time. So when you add the next pump to the Action please type specyfic enter a delay here, for instance, 2 minutes. So the second one pump will dose 2 minutes after the first one. When pumps there are more then than two, then the next pump should be also delayed. See the example below. You can set the delay like thatthis way:

Pump 1: 0

Pump 2: 2

Pump 3: 4

...

Next please click OK

If you want to add next another pump to the Action please click

Status
colourGreen
titleADD TASK
but if
. If you don’t want to add more then please click SAVE click the
Status
colourGreen
titleSAVE
button

...

Tip

...

Congratulations! your first Action is made. Now when your

...

kH level is

...

below the desired level

...

set then the Dosing pump will add the extra

...

quantity.

...

  • How to configure Actions when kH level is above

...

  • specific result

...

  • ?

Again please click

Status
colourBlue
titleADD ACTION

Next please choose Kh KH keeper from the list

...

Please select

Status
titleKh is above

Enter Kh kH level - above this level Dosing pump/s will skip the next dose or part of it. For the example I , we typed 8 (KhkH)

...

Next please select the pump you want to integrate for this Action.

Then we choose to skip part of the next dose

...

Then please click OK

...

Congratulation

Tip

Congratulations you have just added the second Action to your integration. Now when

Kh level

the kH result is above the desired level you can set the Dosing pump

will

to skip part of the next dose. For instance when

Kh

the KH keeper result will be above 8

like

as in this example, then part of the next dose from the chosen Dosing pump is skipped (1-100%).

If you want to add the next Dosing pump to this Action then please click

Status
colourGreen
titleADD TASK
but if you want to add only one then just click
Status
colourGreen
titleSAVE
.

  • How to configure Actions when the kH level is between set limits?

In some cases, you may want your pumps or Power switcher to perform an action when the kH value is between particular values. To add another action please click

Status
colourBlue
titleADD ACTION

Image Added

Next please choose KH keeper from the list

...

Please select

Status
titleKh is Between

Enter kH limits for the

Status
titleKh is Between
Action - when the action is between these values the Action will be executed.

...

Next please select the pump or Power switcher you want to integrate for this Action.

...

In this case, we chose the Power switcher that operates the calcium reactor.

Then we choose to skip part of the next dose

Then please click OK

...

Tip

Congratulations you have just added the third Action to your tank. Now when the kH result is between the desired level you can set one of your Dosing pumps or Power switcher to perform an Action, in this case turning on the Power switcher responsible for the calcium reactor for 15 minutes.

  • Multiple tasks performed under one Action

You can set multiple commands for your action to perform many different tasks when the event is triggered.

If you want to add the next task to this Action then please click

Status
colourGreen
titleADD TASK
but if you want to add only one then just click
Status
colourGreen
titleSAVE
.

If you add several pumps tasks to the Actions then the screen can look like this.

...

Thank you for your time. Those are 2 the first two Actions which that you can use to keep you Kh your kH on your desired level. Next

New Actions for those KH keeper and next other devices will be shre shared with you in near future.