To calibrate the aquarium pump please follow these steps:

  1. Make sure the difference in height between the kH Keeper and the reagent container is not greater than 20 cm.

  2. Put the reagent nozzle comming form coming from the pump to the measuring beaker

  3. Fully fill the tubes using

    Status
    colourYellow
    titleFill the circuit
    button

  4. Please empty the measuring beaker if any liquid is present

  5. Start the calibration process

  6. When the pump stops please measure the amount that it is in the beaker and put the value in the box

Info

Check if the pump is calibrated correctly.

To do this put the tube to into the empty measuring cup and use

Status
colourBlue
titleTest the accuracy
button. The difference should not be greater than 0,05 ml.